Sharing of Air Leak Testing Parameters of Hirays’ Photoelectric Sensor
- Model: Sharing of Air Leak Testing Parameters of Hirays’ Photoelectric Sensor
- Category: Others
- details:
Photoelectric sensor is an important sensitive device which converts optical signal into electrical signal and is widely used. Its working principle is based on the photoelectric effect, which means that when light shines on some substances, the electrons of the substances absorb the energy of photons and the corresponding electric effect phenomenon occurs.
Its air leakage is an important factor affecting the service life of this kind of sensor.
Today, we will share the leak testing parameters of photoelectric sensors.
Testing equipment: HC classic series air leak tester machine
Solution: According to the shape of the photoelectric sensor and customer requirement, design the mold and tooling with wire slots.
Using the indirect test function, put the photoelectric sensor into the mold, press the start button, and the instrument enters the test program. The INPUT PRESS is 10Kpa, the Filling time is 5s, the stable time is 5s, the testing time is 5s, and the Pre-fill time is 4s. The Leak max is 30pa.
If the leak exceeds 30pa during the test, it indicates that the product to be tested is unqualified and is a defective product; If it is not exceeded, it is qualified.
Advantages of Hirays’ air leak tester machine:
l High precision mold processing , up to 0.02mm;
l Leak test, resolution up to 0.1PA;
l Hirays has all product lines of air leakage tester, real water detection and HE leak tester, which can meet the use scenarios of all leakage tests from trial production to mass production;
l Hirays has the ability of rapid system integration, and can deliver goods within 7 days as soon as possible after placing an order;
l The designed testing system strictly considers the stability and accuracy of the test results;